K50-77 OTK

Aluminum electrolytic capacitor

elecond-market@elcudm.ru
+7 (34147) 2-99-89
Конденсатор К50-77
EVAYA.673541.013 TU
Capacitors are used in power converter technology, frequency converters, rectifiers, etc.
Capacitors are suitable for application in direct current and ripple current circuits. Capacitors are produced in all climate version and temperate/cold climate version.
It is recommended to use this capacitor type as substitution for capacitors K50-37, K50-18 types.

Find out about delivery times, product costs or just ask a question

Find out about delivery times, product costs or just ask a question

Main parameters

NameValue
Rated voltage, V16…450
Rated capacitance, µF1 000…100 000
Temporary overvoltage within 10 sec., V1.15 UR (UR ≤ 315)
1.1 UR (UR > 315)
Capacitance tolerance (25 °C, 50 Hz), %+50…-10;  ±20
Maximum operating temperature Tenv, °C+85
Minimal operating temperature Tenv, °C-40
Induction coefficient between terminals, µH≤0.115
Thermal resistance case - environment, max. °С/W4.6

Capasitor physical configuration

Variant A
Temperate/cold climate
version (Isolated)
Temperate/cold climate
version (Nonisolated)
All climate version
(Nonisolated)
All climate version
(Isolated)
Variant B
Temperate/cold climate
version (Isolated)
Temperate/cold climate
version (Nonisolated)
1 – Isolation sleeve
2 – Explosion-proof valve
3 – Connecting strip for discharge
4 – Lacquer coating
5 – Screw BM5-6g
6 – Washer 5.65

Overall and fitting dimensions of a capacitor clamp

Capacitors ratings

UR, V16254063100160250350400450
CR, µF
1 000
1 500
2 200
3 300
4 700
15 000
33 000
100 000

Capacitors overall dimensions and mass

UR, VCR, µF+1.0-0.5 ,mm+0.5-2.0 ,mmA±0.15 mmMass, g, max
16100000508422300
251000005010022320
4033000506622230
6315000506622230
100150005011022350
16047005011022350
2501000506622230
25047006514028.5800
35047006512028.5700
4001000657028.5380
40015006510528.5600
40015006511028.5600
40022006510528.5600
40022006511028.5600
40022006514028.5800
40033006510528.5620
40033006514028.5800
45015006510528.5600
45015006514028.5800

Capacitor electric parameters

UR, VCR, µFtg δ, %, 25°C, 50 Hz, maxILEAK, µA, 25°C, after 5 min., maxZ, Ohm, 25°C, 10kHz, maxIR, А, 85 °C, 50 Hz, maxIR, А, 85°C, 100 Hz, max
161000006080000.0158.811
2510000040125000.0151215
40330003566000.029.812.25
63150002094500.027.39.13
100150001575000.0259.211.5
16047001575200.0445
25010001525000.1133.75
25047001558750.048.811
35047001582250.047.79.6
40010001520000.113.574.46
40015001560000.114.86
40022001588000.056.658.2
40033001566000.047.79.6
45015001567500.0767.5

Operation time (thousands of hours) versus environmental temperature Tenv and the ripple factor of loading current K = I / I ripple

Tenv, °CRipple factor of loading current K
00.60.81.01.21.41.61.8
4011081.367.246.330.117.79.75.3
4582.560.550.034.522.413.27.254.0
5061.845.437.525.816.89.95.42.95
5545.033.027.318.812.27.23.92.11
6043.925.621.214.69.45.53.11.75
6526.019.115.810.97.074.22.31.26
7019.614.411.98.25.33.11.70.93
7513.110.88.96.13.92.31.30.73
809.97.96.64.62.91.70.90.48
858.256.05.03.52.21.30.70.38
Ripple current effective value
versus temperature and frequency can be found from the formula IRO = IR x KT x KF, where

IR– allowable ripple current at 85 °C, 50 Hz (See Table “Capacitor electric parameters”)

KT - IR correction factor versus temperature

Tenv, °C404550556065707580859095100105
KT1.441.401.361.31.251.181.121.071.031.00.910.810.70.56

KF - IR correction factor versus frequency

F, Hz501003001 000≥10 000
KF11.251.441.51.63

Capacitors reliability

Reliability Operation modesMinimal nonfailure operating
time, tλ, hours
Capacitor failure
rate, λ, 1/hour, max
Maximum-permissible mode (0.875UR, Tenv=85°С)5 0005x10-6
Maximum-permissible mode (UR, Tenv=70°С)5 0005x10-6
Storageability
Gamma-rated time of capacitor storageability Tcy at y=99.5%, years, min
10

Coded symbol for capacitors (identification number (partnumber))


Capacitor K50-77 – 40V – 33000µF (±20%) – I – EVAYA.673541.013TU
(K50-77B- S -339M –D50H66-PET-013-UHL)

1

1.1

2

3

4

5

6

7

8

9

Capacitor K50-77

B

40V

33000µF

±20%

D=50mm

H=66mm

PET

EVAYA.673541.013 TU

UHL

K50-77

B

S

339

M

D50

H66

PET

013

UHL

1. K50-77 – capacitor K50-77
1.1 Design variant

Code

The presence of a hairpin

A

Without End Stud (A)

В

With end pin (B)

2. Rated voltage code

Code

E

G

S

K

N

Q

W

T

Y

U

UR, V

16

25

40

63

100

160

250

350

400

450

3. Nominal capacity code

Code

108

158

228

338

478

159

339

1009

CR, µF

1000

1500

2200

3300

4700

15000

33000

100000

4. Capacity approval code

Code

M

T

Admittance, %

±20

+50; –10

5. Condenser diameter code

Code

D50

D65

Diameter, mm

50

65

6. Condenser height code

Code

H66

H70

H84

H100

H105

H110

H120

H140

Height, mm

66

70

84

100

105

110

120

140

7. Isolation code

Code

Decryption

PET

Isolated, packed in box for hand assembly equipment

PET-0

Uninsulated, packed in box for hand assembly equipment

8. Code TU

Code

TU designation

013

EVAYA.673541.013 TU

9. Climatic performance

Code

Decryption

В

Capacitors designed for interior installation with resistance requirements to high air humidity 98% at 35°C

UHL

Capacitors are designed for interior installation with resistance requirements to high air humidity 98% at 25°С (climatic version UHL)

Example of reference designation for ordering

Variant A:
CAPACITOR K50-77 – 400V – 3300µF ±20% BI A EVAYA.673541.013 TU

Variant B:
CAPACITOR K50-77 – 400V – 3300µF ±20% I B EVAYA.673541.013 TU

For case D=65 mm, H=105 mm:
CAPACITOR K50-77 – 400V – 3300µF ±20% I B EVAYA. 673541.013 TU 65×105 mm

Page content

Download detailed catalog capacitors in format PDF
File size: 57.8 Mb
Ask a question to a specialist

Leave your contact details and our specialist will contact you shortly