Leading manufacturer of capacitors in Russia

3, Kalinin Str., Sarapul

Marketing department

Marketing department
Sales department
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
post
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
post

K50-86

Aluminum electrolytic capacitor

elecond-market@elcudm.ru
+7 (34147) 2-99-89
Конденсатор К50-86
TU 6270-008-07628635-2007
Capacitors of compact design, polarized, fixed capacity, with radial screw terminals. Capacitor type is used for operation in direct current, ripple and pulse current circuits. The capacitor is available in all-climate (isolated and non-isolated) and temperate/cold climate version (isolated).

It is recommended to use this capacitor type as substitution for capacitors K50-18, K50-27, K50-37, K50-77 types.

Find out about delivery times, product costs or just ask a question

Find out about delivery times, product costs or just ask a question

Main parameters

NameValue
Rated voltage, V250…485
Rated capacitance, µF1 000…6 800
Temporary overvoltage within 10 sec., V1.15 UR (UR=250)
1.1 UR (UR>250)
Capacitance tolerance (25 °C, 50 Hz), %+30…-10; ±20
Maximum operating temperature Tenv, °C+85
Minimal operating temperature Tenv, °C-40

Capasitor physical configuration

Variant A
Temperate/cold climate
version (Isolated)
All climate version
(Nonisolated)
All climate version
(Isolated)
Variant B
Temperate/cold climate
version (Isolated)
Cap.1st variant (for sizes 65×70; 65×105; 65×140; 76×142; 90×140)
Cap.2nd variant (for sizes76x105; 76×146; 90×146)
D, mmA, mm
6528.5±0.15
7632.0±0.15
9032.0±0.15
1 – Insulating cover
2 – Explosion proof valve
3 – Jumper for discharge
4 – Paintwork
5 – Screw ВМ5-6g (ВМ6-6g for D=76mm as agreed with the consumer)
6 – Washer 5.65 (6.65 for D=76mm as agreed with the consumer)

Overall and fitting dimensions of a capacitor clamp

1 – clamp
2 – screw BM4-6gx12.48.019 GOST 17473
3 – washer A4,0.01.08 kp.019 GOST 11371
4 – nut M4-6N.04.019 GOST 5916
D'D''LMass, g, max
66.2±0.278.688.659.7
77.2±0.289.699.669.6
91.2±0.2103.6113.682.2

Capacitors overall dimensions and mass

UR, V250350400450485
CR, µFDxL,mm
mass, g
1 00065x70
400
1 50065x105
800
65x105
600
2 00076x142
1 100
2 20065x105
800
3 30065x105
600
76x105
740
4 70065x140
800
65x140
800
76x142
1 100
76x146
960
90x140
1 320
6 80090x140
1 400
90x146
1 345

Capacitor electric parameters value when delivered

UR, VCR, µFtg δ, %, 25°C, 50 Hz, maxILEAK, µA, 25°C, after 5 min., maxZ, Ohm, 25°C, 20kHz, maxESR, Ohm, 25°C, 100Hz, maxMspec, g/C⋅h, maxIR, А, 85°C, 50 Hz, max
50 Hz100 Hz
2504 700105 2030.110.10.0418.510.6
3504 7006 1560.050.030.0409.311.6
4001 0002 4660.160.130.0793.74.6
1 5003 0210.110.090.0834.86.0
2 2003 6580.070.060.0576.48.0
3 3005 5140.050.040.0388.811.0
0.0490.0360.04410.713.4
4 7006 5810.0340.030.04211.214.0
6 8009 2350.0240.0240.03415.219.0
4501 5003 2040.150.130.0745.26.5
2 0003 7000.130.090.0886.48.0
4854 7008 4550.080.060.04012.115.1
Ripple current effective value
versus temperature and frequency can be found from the formula IRO = IR x KT x KF, where

IR– allowable ripple current at 85 °C, 50 Hz (See Table “Capacitor electric parameters”)

KT - IR correction factor versus temperature

Tenv, °C254050607085
KT65x70; 65x105; 65x140; 76x142; 90x140 (mm x mm)
1.71.581.461.331.21.0
76x105; 76x146; 90x146 (mm x mm)
2.42.32.22.01.71.0

KF - IR correction factor versus frequency

F, Hz501002003004005001 000≥2 000
KF11.251.41.481.521.541.581.6

Capacitors reliability

Reliability
Operation modes
Minimal nonfailure operating time, tλ, hoursCapacitor failure
rate, λ, 1/hour, max
Maximum-permissible mode (UR, Tenv=85 °С)
size DxH, mm: 65x70; 65x105; 65x140; 76x142; 90x140
12 0005x10-5
Maximum-permissible mode (UR, Tenv=85 °С)
size DxH, mm: 76x105; 76x146; 90x146
13 0005x10-5
Light mode (0.5UR, Tenv=50 °С)
size DxH, mm: 65x70; 65x105; 65x140; 76x142; 90x140
150 0003x10-7
Light mode (0.5UR, Tenv=50 °С)
size DxH, mm: 76x105; 76x146; 90x146
160 0003x10-7
Storageability
Gamma-rated time of capacitor storageability Tcy at y=95%, years, min
20
Service life (UR, Tenv=85 °C), hour, min
size DxH, mm: 65x70; 65x105; 65x140; 76x142; 90x140
size DxH, mm: 76x105; 76x146; 90x146
18 000
20 000
Pulsed service life:
(UR; Tcharge ≥ 0.1 s; Rdischarge ≥ 1 Ohm; 25°C), cycles, min.
106

Coded symbol for capacitors (identification number (partnumber))


Capacitor K50-86 - 250V - 4700µF (±20)% –I– TU6270-008-07628635-2007
(K50-86-W-478M-D65H140-PET-635-2007-UHL)

1

1.1

2

3

4

5

6

7

8

9

Capacitor K50-86

B

250V

4700µF

±20%

D=65mm

H=140mm

PET

TU6270-008-07628635-2007

UHL

K50-86

B

W

478

M

D65

H140

PET

635-2007

UHL

1. K50-86 - capacitor K50-86
1.1 Design variant

Code

The presence of a hairpin

A

Without end pin

B

With end pin

2. Rated voltage code

Code

W

T

Y

U

Y85

UR, V

250

350

400

450

485

3. Nominal capacity code

Code

108

158

208

228

338

478

688

CR, µF

1000

1500

2000

2200

3300

4700

6800

4. Capacity approval code

Code

M

Q

Admittance, %

±20

+30; –10

5. Condenser diameter code

Code

D65

D76

D90

Diameter, mm

65

76

90

6. Condenser Height Code

Code

H70

H105

H140

H142

H146

Height, mm

70

105

140

142

146

7. Isolation code

Code

Decryption

PET

Isolated, packed in a box for manual assembly of equipment

PET-0

Uninsulated, packed in box for hand assembly equipment

8. Code TU

Code

TU designation

635-2007

TU6270-008-07628635-2007

9. Climatic performance

Code

Decryption

В

Capacitors designed for interior installation with resistance requirements to high air humidity 98% at 35°C

UHL

Capacitors are designed for interior installation with resistance requirements to high air humidity 98% at 25°С (climatic version UHL)

Capacitor K50-86IRZ – 400V – 4700µF (±20)% –I– TU6270-008-07628635-2007
(K50-86IRZ - Y -478M-D76H142-PET-635-2007-UHL)

1

1.1

2

3

4

5

6

7

8

9

Capacitor K50-86

B

400V

4700µF

±20%

D=76mm

H=142mm

PET

TU6270-008-07628635-2007

UHL

K50-86

B

Y

478

M

D76

H142

PET

635-2007

UHL

1. K50-86IRZ– capacitor K50-86IRZ
1.1 Design variant

Code

The presence of a hairpin

В

With end pin

2. Rated voltage code

Code

Y

UR, V

400

3. Nominal capacity code

Code

478

CR, µF

4700

4. Capacity approval code

Code

M

Admittance, %

±20

5. Condenser diameter code

Code

D76

Diameter, mm

76

6. Condenser Height Code

Code

H142

Height, mm

142

7. Isolation code

Code

Decryption

PET

Isolated, packed in a box for manual assembly of equipment

8. Code TU

Code

TU designation

635-2007

TU6270-008-07628635-2007

9. Climatic performance

Code

Decryption

UHL

Capacitors are designed for interior installation with resistance requirements to high air humidity 98% at 25°С (climatic version UHL)

Example of reference designation for ordering

CAPACITOR K50-86a – 400V – 4700µF ±20% (76×142) B TU 6270-008-07628635-2007
CAPACITOR K50-86a – 400V – 4700µF ±20% (76×142) B I TU 6270-008-07628635-2007
CAPACITOR K50-86b – 400V – 4700µF ±20% (76×142) I TU 6270-008-07628635-2007

Page content

Download detailed catalog capacitors in format PDF
File size: 57.8 Mb
Ask a question to a specialist

Leave your contact details and our specialist will contact you shortly

Ask a question to a specialist

Leave your contact details and our specialist will contact you shortly

Ask a question to a specialist

Leave your contact details and our specialist will contact you shortly