Main parameters
Name | Value |
---|---|
Rated voltage, V | 250…450 |
Rated capacitance, µF | 1 000…4 700 |
Temporary overvoltage within 10 sec., V | 1.15 UR (UR = 250) 1.1 UR (UR > 250) |
Capacitance tolerance (25 °C, 50 Hz), % | +50…-10; ±20 |
Maximum operating temperature Tenv, °C | +85 |
Minimal operating temperature Tenv, °C | -40 |
Capasitor physical configuration
Variant A
Temperate/cold climate
version (Isolated)
version (Isolated)
All climate version
(Nonisolated)
(Nonisolated)
All climate version
(Isolated)
(Isolated)
Variant B
Temperate/cold climate
version (Isolated)
version (Isolated)
1 – Isolation sleeve
2 – Explosion-proof valve
3 – Connecting strip for discharge
4 – Lacquer coating
5 – Screw BM5-6g
6 – Washer 5.65
2 – Explosion-proof valve
3 – Connecting strip for discharge
4 – Lacquer coating
5 – Screw BM5-6g
6 – Washer 5.65
Overall and fitting dimensions of a capacitor clamp
Capacitor ratings
UR, V | 250 | 400 | 450 |
---|---|---|---|
CR, µF | |||
1 000 | ✓ | ||
1 500 | ✓ | ✓ | |
2 200 | ✓ | ||
3 300 | ✓ | ||
4 700 | ✓ |
Capacitors overall dimensions and mass
UR, V | CR, µF | D, mm | H, mm | A±0.15, mm | Mass, g, max |
---|---|---|---|---|---|
250 | 4 700 | 65 | 140 | 28.5 | 800 |
400 | 1 000 | 65 | 70 | 28.5 | 380 |
400 | 1 500 | 65 | 105 | 28.5 | 600 |
400 | 2 200 | 65 | 105 | 28.5 | 600 |
400 | 3 300 | 65 | 105 | 28.5 | 600 |
450 | 1 500 | 65 | 105 | 28.5 | 600 |
Capacitors reliability
Reliability Operation modes | Minimal nonfailure operating time, tλ, hours | Capacitor failure rate, λ, 1/hour, max |
---|---|---|
Maximum-permissible mode (UR, T=85 °С) | 12 000 | 5x10-5 |
Light mode (0.5UR, Tenv=50 °С) | 150 000 | 3x10-7 |
Storageability Gamma-rated time of capacitor storageability Tcy at y=95%, years, min | 20 |
Capacitor electric parameters
UR, V | CR, µF | tg δ, %, 25°C, 50 Hz, max | ILEAK, µA, 25°C, after 5 min., max | ESR, Ohm, 25°C, 100Hz, max | Z, Ohm, 25°C, 10kHz, max | IR, А, 85°C, 50 Hz, max |
---|---|---|---|---|---|---|
250 | 4 700 | 10 | 5 203 | 0.04 | 0.11 | 8.8 |
400 | 1 000 | 10 | 2 466 | 0.11 | 0.16 | 3.7 |
400 | 1 500 | 10 | 3 021 | 0.09 | 0.11 | 4.8 |
400 | 2 200 | 10 | 3 658 | 0.05 | 0.07 | 6.65 |
400 | 3 300 | 10 | 5 514 | 0.04 | 0.045 | 8.8 |
450 | 1 500 | 10 | 3 204 | 0.07 | 0.15 | 6 |
Ripple current effective value depending on temperature and frequency can be found from the formula:
I = IR × KT × KF,
where IR – allowable ripple current at the temperature 85°C and frequency 50 Hz (See Table “Capacitor electric parameters”)
I = IR × KT × KF,
where IR – allowable ripple current at the temperature 85°C and frequency 50 Hz (See Table “Capacitor electric parameters”)
KT - IR correction factor versus temperature
Tenv, °C | 25 | 40 | 50 | 60 | 70 | 85 |
---|---|---|---|---|---|---|
KT | 1.55 | 1.44 | 1.36 | 1.25 | 1.12 | 1.0 |
KF - IR correction factor versus frequency
F, Hz | 50 | 100 | 200 | 300 | 400 | 500 | 1 000 | ≥2 000 |
---|---|---|---|---|---|---|---|---|
KF | 1 | 1.25 | 1.34 | 1.38 | 1.41 | 1.43 | 1.48 | 1.52 |